Motor Magnet Insertion Equipment: What Are the Standards for Testing Magnetic Field Uniformity After Magnet Insertion? — Jiuju Motor Automatic Assembly Line

Q: Why is it necessary to measure magnetic field uniformity after inserting the magnet?

电机插磁后磁场均匀性影响空载电流,本文给出检测标准与返修判定方法。

磁钢插歪、插反或残留铁屑都会导致rotor磁场不均匀。我们去年给一家做Drone Motors的客户做陪产,同一批转子插磁后空载电流波动达到18%,后来用高斯计逐片扫描发现3片磁钢极性反向。返修后电流波动降到5%以内。磁场不均匀会让电机运行时产生齿槽转矩脉动,高速下噪音明显变大。

Glued Magnet Inserted Finished Product
Glued Magnet Inserted Finished Product

Q: What is the most reliable instrument to use for on-site testing?

Benchtop Gauss meters or rotating scanning stands are commonly used on production lines. Taking a typical φ30mm outer-rotor motor as an example, the scan should include at least 8 evenly spaced points, and the deviation of the magnetic flux density at any single point from the average value must be within ±5% to be considered acceptable. For more stringent applications, such as motors used in drones or automotive electronics, it is recommended to tighten the deviation limit to ±31 TP3T and to record the polar angle of each magnet.

Jiuju Electric Vehicle Magnet Inserting Machine
Jiuju Electric Vehicle Magnet Inserting Machine

Q: What should I do if the test results are unsatisfactory?

First, identify the magnet part numbers with deviations exceeding the tolerance limits to determine whether the issue stems from the incoming magnet material or the insertion depth. If the insertion depth deviation is within 0.2 mm, it can be fine-tuned by applying additional pressure; if the deviation exceeds 0.3 mm or the polarity is reversed, the magnet must be removed and reinserted. Demagnetization checks must be performed on removed magnets; those with surface residual magnetism exceeding 10% should be scrapped immediately to prevent performance drift after being put back into service.