Motor Winding Machine: How to Troubleshoot a Failed Inter-turn Dielectric Withstand Test After Winding?

匝间耐压不合格是Winding后常见不良,排查漆包线、张力与模具可快速定位根因。

Q: What does an abnormal waveform in a turn-to-turn withstand voltage test typically indicate?

波形出现明显衰减或震荡,说明绕组内部存在匝间短路或绝缘薄弱点。常见根因有三类:漆包线本身有针孔或漆瘤、绕线张力过大把漆膜刮伤、模具棱角锋利刮破线皮。我们产线曾有一批0.18mm线径的Product不良率突然升到3.5%,最后排查到是张力轮磨损导致张力波动超过±15%。

Precision Winding
Precision Winding

Q: When troubleshooting, should you check the cables first or the equipment?

先看线材来料。把同一盘漆包线在实验室做针孔试验和漆膜连续性测试,如果每5米针孔数超过3个,优先换料。线材OK后再查设备:张力器设定值是否超过漆包线破断力的30%,过线轮和导针是否有毛刺,排线导程是否顺畅。模具方面,槽口倒角建议做到R0.3以上。

Winding Equipment
Winding Equipment

Q: How should test parameters be set to minimize false positives?

The pulse voltage is set to 2–3 times the motor’s rated voltage, with the rising edge controlled to within 1 μs; this makes the waveform more sensitive to minor short circuits. At the same time, a standard waveform template must be established by using the waveform from the first accepted unit as a reference, against which each subsequent unit is automatically compared for similarity. We generally set the similarity threshold at 85%; values below 80% are immediately judged as NG, while those between 80% and 85% are manually reviewed to avoid misjudging minor variations in normal windings as defects.